Files
gods-eye-view/changelog.d/1267-cctv-hls-capacity-health.md
T
German Khokhlov ed38a1ab3f fix(cctv): keep an HLS camera's health through the refused viewer's frame
A viewer refused for capacity falls back to /frame after hls.js gives up.
For a pullable HLS camera without a snapshot, /frame only has a
placeholder or a Street View frame, which says nothing about the stream,
yet it wrote degraded over the health that /media owns. /frame now
leaves that health as it is; a dead upstream is still reported through
/media.

Tests: the middleware suite covers both fallbacks, a real upstream
failure that still degrades, and cross-site segment and release refusals
on a live HLS lease; capacity checks use HLS_LIMITS and HlsCapacityError;
the three CCTV suites share one provider harness in src/testSupport.
CURRENT-STATE and the changelog fragment describe the refusal.
2026-11-20 11:48:22 +04:00

267 B

  • Stop reporting a live HLS camera as degraded when a viewer is refused because every viewer or session slot is taken: the refusal answers 503 with Retry-After, and the frame shown in its place leaves the camera's health as it was (asturksever, gekh, #1267).