Four test files built the same widget on CesiumWidget.prototype, viewer
proxy, store and notice; renderLoopFixture.mjs now does it once. The notice
test drives Cesium.Event instead of a hand-made double. frameEvents() drops
tileset.tileLoad, which Cesium raises inside its own error handling, and the
notice no longer guards a viewer without a canvas or requestRender.
- An error a frame of the inline panel's timer throws no longer reaches the
host page; it has been raised as a render error by then.
- An error Scene raised and threw on (rethrowRenderErrors) is raised once.
- After a lost context, later render errors are only logged, so the notice
keeps saying why.
- A render error without a value shows no detail.
- The globe's tile load progress and the scene's tileset load events are
finished too when a listener's error cuts them short.
- Focus goes back where it was when the globe draws again, or to the map.
- The appearance counter and the guard for a missing viewer are gone.
Tests cover every finished event, a thrown timer frame, a single report under
rethrowRenderErrors and the focus return; the inline tests share one setup.
An error thrown outside Scene's own error handling (a postRender listener,
the clock's onTick, a resize) stopped Cesium's loop without a renderError,
and with Cesium's panel turned off the globe froze silently. The notice now
raises such an error as a render error.
In an inline panel whose host stopped animation frames, Retry left the
panel's timer latched off, and once frames resumed a second render loop
drew every frame twice. The timer now follows Cesium's loop, and keeps the
loop marked running when its next frame is still queued.