Review fixes: station panel and model housekeeping, label-box click, telemetry null stamp

- Installations: the label-box click fallback reaches the controls' methods
  (it read an undefined member and never ran).
- Station model: the docked-companion scan runs once a second again; the
  hand-over pass runs once, when the model starts drawing.
- Station panel: an unchanged view is not republished every frame; one
  render pump across slider drags, stopped on destroy; destroying the panel
  hands the joints back to Automatic, and the joint drivers' reset forgets
  manual choices and the telemetry lock.
- Telemetry relay: a null TimeStamp is no time, not the first second of the year.
- Drop issCommandShouldShow and issCommandNoteText, which nothing called.
This commit is contained in:
Denis Groshev committed 2026-11-16 19:31:32 +01:00
1 parent ae9cfa4ffb
commit aeaa192b5f
8 files changed
+63 -77

No files matched your search

+1 -1
View File
@@ -62,7 +62,7 @@ export function createSelection({
parts.rendering.ownsSet(hit?.set)
? hit.meta?.installationId
: null) ??
parts.controls?.findAt?.(event.position)?.id ??
parts.controls?.methods?.findAt?.(event.position)?.id ??
null;
if (id && layerState.recordById.has(id) && id !== layerState.selectedId) {
selectRecord(id);